| CSN Number: |
02050604 |
Date: |
05.06.2002 |
| Submitted by: |
Laura Shay |
|
|
|
| |
MC9000
and MeetingPoint 4.6 Data Sharing
and Collaboration issues |
| |
| Emblaze-VCON Product: |
Escort Ver:4.6, Cruiser 75/150 ver:4.6, Cruiser 384 ver:4.6
MC8000 ver:4.6, MC9000 ver:1.0, ViGOver:4.6 |
| Non-Emblaze-VCON Product: |
NetMeeting ver:3.01 |
|
| |
Problem Description:
Data sharing and collaborating does not work properly |
| |
Resolution:
MeetingPOint 4.6 and MediaConnect 9000 utilize NetMeeting 3.01. Trying
to collaborate from MeetingPoint 4.01 (or older) or any other vendor system
that uses Netmeeting 2.1 to MeetingPoint 4.6 or MediaConnect 9000 will result
in a failure.
1. If you have other Emblaze-VCON desktop systems, installed with previous MeetingPoint
versions, upgrade them to MeetingPoint 4.6.
2. If you have other vendor's systems, upgrade the NetMeeting on them
to version 3.01.
3. Initiating the collaboration from NetMeeting 3.01 side to NetMeeting
2.1 side will result in success.
|
| |
Related Notes or Documents:
none |
| |
| Back |
| |
| |
|
| |
|
|
|
|
|
|